Questions and Answers

  • S
    Stephanie GreenAug 20, 2025
    Why is the power supply unit LED not lit on my Mellanox Technologies IS5030Q-1SFC?
    • A
      Aaron HudsonAug 20, 2025
      If the power supply unit LED is not lit or is red, try the following: * Ensure the power cable is correctly plugged into a working outlet. * Verify the power cable's voltage is within the range of 100-240 volts AC. * Confirm the airflow direction of the PSUs aligns with the fan module airflow. * Try removing and reinstalling the power cable. * Try removing and reinstalling the PSU.
  • J
    James BrownAug 22, 2025
    What to do if my Mellanox Technologies IS5030Q-1SFC Switch is not working and unresponsive?
    • S
      stephanie66Aug 22, 2025
      If your Mellanox Technologies Switch is unresponsive, try these steps: 1. Reset the switch. 2. If resetting doesn't work, unplug the switch. 3. Wait 5 minutes. 4. Plug the switch back in. 5. If the switch still doesn't power on, check the power supplies. 6. If the switch powers on, use the FabricIT management CLI or Web GUI to find the cause of the shutdown.
  • E
    Eric GonzalesAug 25, 2025
    What to do if Mellanox Technologies IS5030Q-1SFC Switch is off?
    • M
      Matthew MurphyAug 25, 2025
      If your Mellanox Technologies Switch is off, follow these steps: 1. Unplug the switch. 2. Wait 5 minutes. 3. Plug the switch back in. 4. If it doesn't turn on, check the power supplies. 5. If it does turn on, use the FabricIT management CLI or Web GUI to determine why it shut down. 6. Check the temperature. 7. Check the fan status.
  • M
    Molly WalkerAug 27, 2025
    How to fix Mellanox Technologies IS5030Q-1SFC Switch power LED shutting off?
    • B
      Brandi FernandezAug 27, 2025
      If the power LED for your Mellanox Technologies Switch is off, ensure adequate ventilation. Check for obstructions blocking the front or rear of the chassis. Make sure the fan modules and ventilation holes are not blocked, especially by dust. If dust is present, clean the fan unit and remove dust from the front and rear panels using a vacuum cleaner.
  • J
    Jessica LinAug 28, 2025
    Why is the link LED for the InfiniBand connector not coming on for Mellanox Technologies IS5030Q-1SFC?
    • M
      Mark BrownAug 28, 2025
      If the link LED for the InfiniBand connector on your Mellanox Technologies Switch doesn't light up: * Verify that both ends of the cable are securely connected. * Ensure the locks on the cable ends are secured. * Confirm that the latest firmware version is installed on both the HCA and the switch. * If using media adapters, check that all connections are good, tight, and secure.
  • R
    Renee WilliamsAug 29, 2025
    What to do if the green power LED for the fans does not come on in Mellanox Technologies Switch?
    • M
      Miss Wendy RoseAug 29, 2025
      If the green power LED for the fans on your Mellanox Technologies Switch is not lit: * Check that the Power LEDs are on. * Remove and reinstall the fan unit, ensuring the mating connector of the new unit is free of any dirt or obstructions.
  • B
    Brittany SparksAug 31, 2025
    What to do if the activity LED does not come on for Mellanox Technologies IS5030Q-1SFC Switch?
    • K
      Karen DiazSep 1, 2025
      If the activity LED on your Mellanox Technologies Switch does not illuminate, verify that the Subnet Manager has been started.
  • M
    Mark HernandezSep 2, 2025
    What to do if Status LED and or Status Health LED is red on Mellanox Technologies IS5030Q-1SFC?
    • D
      Dawn HopkinsSep 3, 2025
      Unplug the Mellanox Technologies Switch and call your Mellanox representative.
  • C
    Colleen MooreSep 4, 2025
    What to do if the LED on the Mellanox Technologies IS5030Q-1SFC Switch power supply unit is not lit?
    • Z
      zcooperSep 4, 2025
      If the LED on the PSU is not lit or is red, ensure the power cable is properly connected to a working outlet and that it supports a voltage within the range of 100 - 240 volts AC. Also, verify that the airflow direction of the PSUs is consistent with the Fan module airflow. If issues persist, try removing and reinstalling the power cable, and then the PSU itself.
  • S
    Sandra WilliamsSep 6, 2025
    How to fix the InfiniBand connector link LED if it's not on for Mellanox Technologies Switch?
    • R
      Rachel BernardSep 6, 2025
      First, check that both ends of the cable are securely connected and that the locks on the ends are fastened. Ensure that the latest firmware version is installed on both the HCA and the switch. If you are using media adapters, verify that all connections are properly secured.

Summary

Revision History

About this Manual

Intended Audience

Describes the target users for the manual.

Related Documentation

Lists other Mellanox documents relevant to the switch.

Conventions

Explains terms and abbreviations used throughout the manual.

Mellanox Part Numbering Legend

Overview

Serial Number and Product Version Information

Details where to find serial numbers and GUIDs for the switch.

License Key

Explains the location and purpose of the FabricIT license key.

Internally Managed vs. Externally Managed

Basic Operation and Installation

Switch Platform Hardware Overview

Describes the physical components and layout of the switch.

Management and Tools Overview

Network Management and Clustering Software

Details the Mellanox OpenFabric software package for network management.

Internally Managed Switch System

Describes the management features of internally managed switches.

Troubleshooting

Status LED and or Status Health LED

Guides on interpreting status LED indicators for troubleshooting.

The switch is not working and unresponsive

Provides steps to diagnose and resolve unresponsive switch issues.

The last software update did not succeed

Offers solutions for failed firmware update attempts.

Specification

EMC Certifications

Lists regions where the switch has approved EMC certifications.

EMC Statements

Provides specific EMC compliance statements for various regions.

Passing the Power Cord From the Connector Side to the Power Side

QSFP Interface

RJ45 CONSOLE Interface

Replacement Parts Ordering Numbers

Special Regulations Regarding Finland, Sweden, Denmark, and Norway