EasyManua.ls Logo

Mendota FV44i-0616 User Manual

Mendota FV44i-0616
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MODEL NO. FV44i - 0616
FullView Direct Vent Gas Fireplace Insert Heater
Installation & Operating Instructions
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
WH
AT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: If the information in these
instructions are not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gassed, unless
a certified kit is used.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mendota FV44i-0616 and is the answer not in the manual?

Mendota FV44i-0616 Specifications

General IconGeneral
ModelFV44i-0616
TypeIndoor Fireplace
Fuel TypeNatural Gas or Propane
Vent TypeDirect Vent
Ignition TypeElectronic Ignition
BTU/hr Input31, 000 BTU/hr
FinishBlack

Summary

Safety and Warning Information

Building Permit and Installation Inspection Approval Requirements

Requirements for permits, inspections, and warranty validation.

Safety Warnings

General safety precautions and warnings for product use and installation.

General Information

Electrical Requirements

Details on power supply, grounding, and electrical connections.

Specifications

Required Clearances

Essential clearance measurements to combustibles for safe installation.

Hearth Protection Pad Requirements

Venting Requirements

General Venting Requirements

Overview of the venting system components and general installation rules.

Venting Installation Instructions

Step-by-step instructions for installing the venting system.

Electrical Requirements

Gas Supply Requirements

Gas Pressure Checking

Procedures for checking and setting gas pressures during installation.

Converting Insert for LP Gas

Orifice Size Requirement

Specifies the correct orifice sizes for converting to LP gas.

Procedure to Convert Insert for LP Gas

Step-by-step guide for converting the fireplace from Natural Gas to LP Gas.

LP Pressure Regulator Conversion Instructions

Detailed instructions for replacing the pressure regulator for LP gas.

Installation Check Off List

Lighting Check Off List

Using the Remote Control

Remote Control Transmitter Operating Instructions

Detailed instructions on operating the fireplace using the remote transmitter.

First Time Lighting Instructions

Safety Information

Essential safety precautions to read before lighting the appliance.

Operating Instructions

Step-by-step guide for the initial lighting sequence of the fireplace.

Trouble-Shooting

Trouble-Shooting Mendota Gas Inserts

Specific table detailing symptoms, probable causes, and corrective actions for inserts.

Maintenance

Required Annual Maintenance

Annual maintenance procedures to be performed by a service person.

Mendota Warranty & Service Form

Mendota Lifetime Warranty

Related product manuals