38
3. Remove the HEPA lter.
4. Open the dustbin lid and take out the
primary lter.
5. Empty the dustbin.
6. Wash the dustbin and primary lter, and
allow to dry.
7. Brush o the HEPA lter.
8. Replace the HEPA lter and primary lter
in the dustbin.
FIG. 13
FIG. 14
FIG. 15
NOTE:
Wash the primary lter after 15–30 days
of use.
The maximum lifespan of the HEPA lter
is 24 months.
Allow the primary lter to completely
dry before replacing it. Do not dry the
lter in direct sunlight or in a drying
cupboard.
Replace the HEPA lter and primary lter
when necessary.
Do NOT wash the HEPA lter.
Sensors and wheels
If the side brushes do not rotate or if the
vacuum cleaner goes in circles this can be
because hairs etc. have fastened round the side
brushes or wheels. Remove dirt and hairs from
the brushes and wheels. Carefully wipe all the
sensors and wheels with a soft cloth or brush.
FIG. 16
Charging connectors
Clean the charging connectors with a soft cloth
or brush.
FIG. 17
Suction inlet and dust sensor
Remove the dustbin from the vacuum cleaner
and clean the suction inlet and dust sensor
with a soft cloth or brush.
FIG. 18
REPLACE THE BATTERY
1. Undo the screws on the battery cover with
a screwdriver. The battery lid is located
underneath the vacuum cleaner and is
locked with two screws.
2. Remove the battery lid.
3. Grip the strap on each side of the battery
and lift out the battery.
4. Release the lead from the battery.
5. Connect the lead to the new battery.
6. Put the battery in the vacuum cleaner.
7. Replace the battery cover.
8. Lock the battery cover with the two screws.
IMPORTANT:
Only use batteries of the same type as the
one supplied, otherwise there is a risk of
material damage.