Once the "TRANSFER" button is pressed, the transfer LED will light up and one beep will
sound. Press the "TRANSFER" button again to complete the helm transformation. When
helm transformation is complete, another beep will sound and the transfer LED will turn
off.
NOTE: There is a 10 second time frame to complete a helm transfer. If the helm transfer
is not completed, the action will be cancelled and a double beep will sound. Pressing the
"TRANSFER" button again will re-initiate a helm transfer.
SYNCHRONIZING HELMS PRIOR TO TRANSFER
Pressing the "TRANSFER" button allows the boat operator 10 seconds to match up the
control handle settings at the new helm with the handle settings that are at the old (to be
inactive) helm. If the handles are not matched, the neutral lights will flash. The light blinks
faster as the handles are nearing match position. Once the light stays on continuously,
the handles are matched and the button can be pressed again to complete the transfer.
This completes the transfer process, and gives control to the new station. If the helm
transfer is not completed within 10 seconds, the action will be cancelled.
Helm Calibration with the Computer Diagnostic System
CDS Connection to the Helm
Computer Diagnostic System (CDS) Order through SPX
4520
Monitors all electrical systems for proper function,
diagnostics, and calibration purposes. For additional
information, pricing, or to order the Computer Diagnostic
System contact:
SPX Corporation
28635 Mound Rd.
Warren, MI 48092
or call:
USA - 1-800-345-2233
Canada - 800-345-2233
Europe - 49 6182 959 149
Australia - (03) 9544-6222
1. Connect the CAN 1 diagnostic cable between the junction box and the CDS
SmartComms box.
Can 1 Diagnostic Cable 84-892663
4680
Connects into a junction box or male to male adapter cable
for Command Module configuration. Not for use with DDT.
2. Connect the SmartComms box to the CDS tool.