INSTRUCTION MANUAL ME-104 13
before sealing to avoid the film to retract on the mattress advance. Is useful for sticky film
ALTERNATE BUTTON PRESS M3: when activated, the press on the 3
rd
module
descends to approach the edges of the mattress and increase the adjustment of the bag before
sealing. Don’t use it with hard beds (wood)
ALTERNATE BUTTON DARK/LIGTH: this button works only with the polarity of the
barrier photocell FC1: when DARK, the barrier photocell FC1 need to be OFF while the
mattress is passing. When LIGTH, need to be ON
BUTTON PWD: give access to the password table, to change or add new users
BUTTON HEATING: give access to the heating menu (see below)
BUTTON MEASURES: give access to the measures menu (see below)
XTRA ADVANCE: time in cents of second while the mattress stays advancing over the
central welding bar. A higher value induces bigger advance before soldering, and the bag will
be looser. The first value will be applied by the machine when X13 is OFF (the second, when
ON). Aprox. values: 10-30
LENGTH ADJUSTMENT: time in cents of seconds (+/-) that is subtract from the
measure in Module nº1 to adjust the aperture of the bars in Module nº3. This adjustment can
also be achieved by approaching or separating the inductive detectors of this parts. A positive
value will provoke a bigger separation in module nº3 Aprox.: 0
ADVANCE PRESS M3 (when equipped): advance of the press in Module nº3 over the
mattress to approach their faces and assure the traction. After this advance, the welding bar
down to make the join. Aprox.: 7-12
MAX. PRESS M3: the first value shows the maximum number of teeth that the press
will count before activate the seal, even if it is not mattress detected. Is only for sizing
purposes, the second number shows the number of teeth already counted, and helps to
calculate the first
TIME PRESS M1: time in tenth of seconds during which the wheels over conveyor in
Module nº1 push on the mattress to assure the traction. After this time, the wheels up to avoid
a shock against the conveyor. Aprox.: 10-20
DELAY PRESS M2: time in tenth of seconds during which the wheels over conveyor in
Module nº2 wait to push on the mattress to assure the traction. This permit the mattress to start
advance during wrapping. Aprox.: 10-20