EasyManua.ls Logo

MERELLO ME-104 - Measures Menu and Parameters

MERELLO ME-104
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTRUCTION MANUAL ME-104 14
MEASURES MENU
BUTTON DEFAULT: load the default parameters value. Also allows to change the
language of the messages
SELECTOR AUTO/MANUAL: select between automatic adapt to the measures of the
mattress or not
BUTTON BARRIER: allows to work with an additional protection barrier at the output
BUTTON UNSTICK: provokes the machine to make a small movement of the rollers in
order to unstuck the film for the next mattress
T-RETRO ROLLER: time in tenth of seconds during which the upper and lower rollers
reverse their rotation after wrapping, for stretch and recover the excess of film. Aprox.: 5-10
EXIT TIME: time in tenth of seconds during which the conveyor in Module nº3 is
running after welding to allow mattress leave the machine. A value higher than necessary will
delay the entrance of the next unit. Aprox.: 30-60
MINIMUM LENGTH: maximum advance of the measuring bar in module nº1 to avoid it
to shock against the conveyor. The mattress will be wrapped even if is littler than this. Aprox.:
250
SIZE M2: value relative to the length of the second conveyor, in order to activate the third
conveyor when the mattress exceeds the corresponding size. A bigger makes the third
conveyor to start later. Aprox.: 40-60
SIZE M3: value relative to the distance between bars in module nº1 and bars in module
nº3, in order to calculate the necessary advance of the mattress. A bigger value provokes the
mattress to advance more. The right value makes the mattress to stop in the beginning of the
module nº3. Aprox.: 200-300