INSTRUCTION MANUAL ME-104 14
MEASURES MENU
• BUTTON DEFAULT: load the default parameters value. Also allows to change the
language of the messages
• SELECTOR AUTO/MANUAL: select between automatic adapt to the measures of the
mattress or not
• BUTTON BARRIER: allows to work with an additional protection barrier at the output
• BUTTON UNSTICK: provokes the machine to make a small movement of the rollers in
order to unstuck the film for the next mattress
• T-RETRO ROLLER: time in tenth of seconds during which the upper and lower rollers
reverse their rotation after wrapping, for stretch and recover the excess of film. Aprox.: 5-10
• EXIT TIME: time in tenth of seconds during which the conveyor in Module nº3 is
running after welding to allow mattress leave the machine. A value higher than necessary will
delay the entrance of the next unit. Aprox.: 30-60
• MINIMUM LENGTH: maximum advance of the measuring bar in module nº1 to avoid it
to shock against the conveyor. The mattress will be wrapped even if is littler than this. Aprox.:
250
• SIZE M2: value relative to the length of the second conveyor, in order to activate the third
conveyor when the mattress exceeds the corresponding size. A bigger makes the third
conveyor to start later. Aprox.: 40-60
• SIZE M3: value relative to the distance between bars in module nº1 and bars in module
nº3, in order to calculate the necessary advance of the mattress. A bigger value provokes the
mattress to advance more. The right value makes the mattress to stop in the beginning of the
module nº3. Aprox.: 200-300