MI SWACO MONGOOSE PRO Shale Shaker
35 Field Installation and Operation Manual 9092F02001AENG (D) 35
15.4 Maintaining Motors
NOTE
INSTALLATION OF VIBRATORY MOTOR SHOULD BE COMPLETED BY A CERTIFIED
ELECTRICIAN.
15.4.1 Lubricating Motor Bearings
Operators must lubricate Motor Bearings every 2000 Operational Hours to maintain optimum performance and
reliability.
TIP
ONLY USE KLUBER ISOFLEX TOPAS NB52 LUBRICANT TO OIL THE BEARINGS.
FAILURE TO DO SO WILL VOID THE MOTOR MANUFACTURER WARRANTY.
4. Remove plugs, one for each bearing (Refer to Figure 29).
5. Insert a 1/8” NPT Zerk grease fitting.
6. Pump 1.41 ounces (40 g) of lubricant into each bearing for normal bearing surface temperatures below
195°F (91°C).
CAUTION
DO NOT OVERFILL GREASE FITTINGS. ADDING TOO MUCH GREASE WILL CAUSE
OVERHEATING AND DESTROY THE MOTOR.
Figure 29. Grease Fittings (Circled)

Table of Contents