MI SWACO MONGOOSE PRO Shale Shaker
43 Field Installation and Operation Manual 9092F02001AENG (D) 43
17.2 Electrical Troubleshooting Table
CAUTION
ELECTRICAL TROUBLESHOOTING EXAMINATIONS MUST BE CONDUCTED BY A
CERTIFIED ELECTRICIAN. FAILURE TO COMPLY COULD RESULT IN ELECTRICAL
SHOCK OR DAMAGE TO EQUIPMENT.
Problem: Both Vibratory Motors Fail to Rotate
Possible Cause: Main power supply shut down.
Remedy: Check supply to control box.
Remedy: Make sure the electrical isolator is on.
Remedy: Check control panel circuit breakers for blown/missing fuses.
Problem: One Vibratory Motor Fails to Rotate
Possible Cause: Damaged wiring.
Remedy: Check wiring for damage, repairing and replacing as necessary.
Possible Cause: Damaged vibratory motor.
Remedy: Have motor components analyzed for wear or damage by a certified electrician.
Possible Cause: Damaged overload contact.
Remedy: Check control panel circuit breakers. Make sure outlet is active.
Remedy: Check the overload in the control panel
Problem: Shaker Operation Stops
Possible Cause: Control circuit tripped.
Remedy: Check circuit breakers and thermal overloads in the control panel, resetting and replacing as
necessary.