MICRO-AIR EasyStart 364 - Polar Cub #2

MICRO-AIR EasyStart 364
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Other Models
20
©2018 Micro-Air Rev 1.01
Polar Cub #2
This version is an alternate wiring supplied with some models. The red X’s in the PTCR, start capacitor,
YEL, and RED wires are all components that must be removed if they are installed. Not all systems have these
components. If the run capacitor has only a single red wire on the HERM terminal or a single red wire on the
terminal group opposite the white/yellow wire group then there is no start components and the red X’s can be
ignored.
The red X by the run capacitor indicates the white wire is disconnected from the yellow wire terminal
and reconnected to the BROWN wire from EasyStart.