DOC 4380A
4380A O & M Manual
51
098-00723-000 Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual
antenna included with the unit. If you are not using the supplied antenna the system may be
connected to a single frequency (L1) antenna.
E. Both fans should be operating properly.
[hardware]
[fan]
[1] true
[2] true
F. Verify the system hardware is operating properly by ensuring the system is displaying the proper
serial number, the outputs are enabled, the power supply status is good and it displays the correct
model #.
[mainboard]
[EUID] 00:30:96:02:00:00:00:f6
[serialnum] U12121
[type] 4380A
[outputs]
[enabled] true
[slots]
[1]
[ports]
[1]
[status] good
[2]
[status] good
[3]
[status] good
[4]
[status] good
[power] enabled
[type] 4394A
[2]
[type] empty
[3-6] Should reflect the installed card.
Note: Slots [1-6] will display information based on which slots have cards in them and what type of
cards are installed. If a card is not installed the type will be empty.
G. The warmstart table may be true or false. If the unit has been running for under an hour this may
be false.
[warmstartable] true Filter has enough data to warm start the system during a
restart/reboot.
H. The power supply status should show both power supplies operating normally. The slots fields
should show which cards are installed in each slot (or empty if no card is present), the port status
for all four outputs are good (=1) and power is enabled.
[power]
[numsupplies] 2
[supplies]
[1]
[status] good
[type] 4385A
[2]
[status] good
[type] 4385A
I. The system will also report the internal temperature as measured by the unit.
[temperature] 37
J. Each of the units hardware conditions is monitored and reported as system health should report
false and have zero active errors.
[health]
[clock_freq_step]
[active] false
[occurrences] 0
[clock_phase_step]