Installation and user manual | 5
HEAT PUMP MICROWELL HP COMPACT
3. PRODUCT DESCRIPTION AND TECHNICAL SPECIFICATION
3.1 Technical data
HP 900 COMPACT HP 1200 COMPACT
Air temperature/water temperature
Heating output (kW) 9.03 8.57 12.01 11.07
Power consumption (kW) 1.55 1.57 2.06 2.03
Coefficient of Performance (C.O.P.) 5.80 5.44 5.81 5.45
Recommended swimming pool capacity (m
/h)/pressure loss (kPa) 4-6/2-8 4-6/2-8
Feeding voltage/Protection (V/A) 230 / 20/1C 230 / 20/1C
Current-carrying capacity/max. current (A) 9.1 10.6
Coverage/Protection IP X4/by zeroing IP X4/by zeroing
Heat exchanger Titan Titan
Acoustic pressure level dB (A) 1m/2m/4m/8m 54/48/42/36 55/49/43/37
Water circuit connection (mm/cól, thread) 50/ 6/4“ internal 50/ 6/4“ internal
Max. recommended pipe length (m) 30 30
Net unit dimensions (w/h/d) 870/950/320 870/950/320
Gross unit dimensions (w/h/d) 1020/1080/450 1020/1080/450
Net/Gross weight (kg) 67/73 69/75
Refrigerant/filling weight (type/kg) R410A/1.27 R410A/1.60
* The manufacturer reserves the right to change the parameters without any advance warning.
3.2 Swimming pool water parameters
The heat pump is designed for heating the swimming pool water, that must be in accordance with the
related sanitary requirements.
The limit values for the heat pump operation are the following: pH value ranging from 6.8 to 7.9; total
chlorine amount not exceeding 3 mg/l.
It is advised to keep the water hardness on the lower limit of the optimal range, i.e. closely above 8
°N.
3.3 Heat pumps dimensions
Water outlet
6/4“inner/l 50mm
870
546
WARNING: The manufacturer
reserves the right to make
modifications and innovations on the
product that do not have any
negative impact on its technical