3.1 Technical data
HP 900 COMPACT HP 1200 COMPACT
Air temperature/water temperature
25°C/10°C
25°C/20°C
25°C/10°C
25°C/20°C
Heating output (kW) 9.03 8.57 12.01 11.07
Power consumption (kW) 1.55 1.57 2.06 2.03
Coefficient of Performance (C.O.P.) 5.80 5.44 5.81 5.45
Recommended swimming pool capacity (m
3
) (with
a cover/without a cover)
40/30 60/40
Energy class A A
Operating temperatureair (°C) 5-40 5-40
Optional swimming pool water temperature range (°C) 5-40 (60) 5-40 (60)
Air flow (m
3
/h)
2520
Recommended water flow (m
3
/h)/pressure loss (kPa) 4-6/2-8 4-6/2-8
Feeding voltage/Protection (V/A) 230 / 20/1C 230 / 20/1C
Current-carrying capacity/max. current (A) 9.1 10.6
Coverage/Protection IP X4/by zeroing IP X4/by zeroing
Heat exchanger Titan Titan
Acoustic pressure level dB (A) 1m/2m/4m/8m 54/48/42/36 55/49/43/37
Water circuit connection (mm/cól, thread) 50/ 6/4“ internal 50/ 6/4“ internal
Max. recommended pipe length (m) 30 30
Net unit dimensions (w/h/d) 870/950/320 870/950/320
Gross unit dimensions (w/h/d) 1020/1080/450 1020/1080/450
Net/Gross weight (kg) 67/73 69/75
Refrigerant/filling weight (type/kg) R410A/1.27 R410A/1.60
* The manufacturer reserves the right to change the parameters without any advance warning.
3.2 Swimming pool water parameters
The heat pump is designed for heating the swimming pool water, that must be in accordance with the
related sanitary requirements.
The limit values for the heat pump operation are the following: pH value ranging from 6.8 to 7.9; total
chlorine amount not exceeding 3 mg/l.
It is advised to keep the water hardness on the lower limit of the optimal range, i.e. closely above 8
°N.
3.3 Heat pumps dimensions
Water outlet
6/4“inner/l 50mm
Water inlet
6/4“inner/l 50mm
Controller
Power supply
230V/50Hz
470 70
695
875
965
940
425
360
320
870
546
WARNING: The manufacturer
reserves the right to make
modifications and innovations on the
product that do not have any
negative impact on its technical
feautures and parameters.