TROUBLESHOOTING
Safety
Fig. 15 —Electrolytic Capacitors
For other models, please connect discharge resistance (approximately 100 40W) or a soldering iron (plug) between the +, - terminals of the
electrolytic capacitor on the contrary side of the outdoor PCB.
Fig. 16 —Discharge Position
NOTE: Fig. 16 is for reference only. The plug on your unit may differ.
UNIT DAMAGE HAZARD
Electricity remains in capacitors even when the power supply
is off. Ensure the capacitors are fully discharged before
troubleshooting.
Lock out and tag switch with a suitable warning label.