211
17.4.4 Fan speed malfunction diagnosis and solution (F5)
Error Code
F5
Malfunction conditions
When outdoor fan speed is too low or too high for a certain
period of time, the unit ceases operation and the LED displays a
failure code.
Potential Causes
Wiring mistake
Faulty fan assembly
Faulty fan motor
Faulty PCB
Trouble shooting:
YES
Power off, then restart the unit after 2 minutes.
Is it within normal parameters?
Replace the fan motor
Does a problem remain? The unit is operating normallyNO
Shut off the power supply, Rotate
the fan by hand.
YES
Does it turn easily? Find the cause of the problem and resolve itNO
Check the wiring of fan motor.
YES
Is it improperly wired?
Ensure proper connections
Measure the voltage for
the fan motor from the PCB.
YES
Replace the outdoor main PCB
NO
Replace the DC motor driver board
(if has)