EasyManuals Logo
Home>Midea>Dehumidifier>MDT1-08DMN3-QA3

Midea MDT1-08DMN3-QA3 User Manual

Midea MDT1-08DMN3-QA3
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
18
9 Characteristic of temperature sensor
10 Troubleshooting
In general, possible trouble is classified in three kinds. One is called Starting Failure which is caused
from an electrical defect, another is ineffective Air Conditioning caused by a defect in the refrigeration
circuit and improper application, and the other is called the Structure Damage.
Temp.
Resistance
Temp.
Resistance
Temp.
Resistance
-10
62.2756
17
14.6181
44
4.3874
-9
58.7079
18
13.918
45
4.2126
-8
56.3694
19
13.2631
46
4.0459
-7
52.2438
20
12.6431
47
3.8867
-6
49.3161
21
12.0561
48
3.7348
-5
46.5725
22
11.5
49
3.5896
-4
44
23
10.9731
50
3.451
-3
41.5878
24
10.4736
51
3.3185
-2
39.8239
25
10
52
3.1918
-1
37.1988
26
9.5507
53
3.0707
0
35.2024
27
9.1245
54
2.959
1
33.3269
28
8.7198
55
2.8442
2
31.5635
29
8.3357
56
2.7382
3
29.9058
30
7.9708
57
2.6368
4
28.3459
31
7.6241
58
2.5397
5
26.8778
32
7.2946
59
2.4468
6
25.4954
33
6.9814
60
2.3577
7
24.1932
34
6.6835
61
2.2725
8
22.5662
35
6.4002
62
2.1907
9
21.8094
36
6.1306
63
2.1124
10
20.7184
37
5.8736
64
2.0373
11
19.6891
38
5.6296
65
1.9653
12
18.7177
39
5.3969
66
1.8963
13
17.8005
40
5.1752
67
1.83
14
16.9341
41
4.9639
68
1.7665
15
16.1156
42
4.7625
69
1.7055

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MDT1-08DMN3-QA3 and is the answer not in the manual?

Midea MDT1-08DMN3-QA3 Specifications

General IconGeneral
BrandMidea
ModelMDT1-08DMN3-QA3
CategoryDehumidifier
LanguageEnglish

Related product manuals