EasyManua.ls Logo

Midea MFJ-48ARN1-RB6 - Electronic Function; Performance Index; Main Data Introduction; Manual Operation

Midea MFJ-48ARN1-RB6
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electronic function
17
7 Electronic function
7.1 Performance Index
No. Item Index
1 Applicable Voltage Range 185-253V, 342-418V
2 A/C Frequency 50Hz
3 Working environment temperature -7°C- +45°C
7.2 Main data Introduction
Ts : Set temperature,
T1 : Room temperature
T2: Evaporator pipe temperature
7.3 Operation Modes and Functions
7.3.1 Manual Operation
7.3.2 Heating Mode
7.3.2.1 Four-way valve opens at once, while defrosting process closes.
7.3.2.2 Condition for the compressor action: (Ts=set temperature, T1=room
temperature)
7.3.2.3 Indoor Fan Action
Anytime remote switchover for fan speed among high/low/auto, anti-cold air function takes
priority.
Auto fan in heating mode
Anti-cold air:
Switchover between fan speed and fine tune can be set according to temperature of evaporator
pipe (T2).
Condition Compressor and outdoor fan
Room temperature up T1-Ts=0°C Off
T1-Ts>-1°C On
Room temperature down T1-Ts<-1°C On
T1-Ts=0°C Off
Condition Fan speed
Room temperature up T1-Ts>-1°C Low
T1-Ts<-1°C Hi.
Room temperature down T1-Ts<-2°C Hi.
-2°C <T1-Ts <-1°C Low
Condition Fan speed
Room temperature up T2<25°C Off
25°C <T2<3C Low
T2>32°C Set fan speed
Room temperature down T2>22°C Set fan speed
20°C <T2<2C Low

Related product manuals