T4    Outdoor temperature(°C)
T1    Water flow temperature(°C)
DOMESTIC WATER HEATING  MODE
T4
T1
30
43
-2
-20
■    No heat pump operation, backup heater or boiler only.
1.2 Scope of this manual
    This installation & owner's manual describes the procedures for 
installing and connecting all monobloc outdoor unit models.
DANGER
Indicates an imminently hazardous situation which if not 
avoided, will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which if not 
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury. It is also 
used to alert against unsafe practices.
NOTE
Indicates situations that could only result in accidental 
equipment or property damage.
■  Before touching electric terminal parts, turn off power switch.
■  When service panels are removed, live parts can be easily
    touched by accident.
    Never leave the unit unattended during installation or servicing 
    when the service panel is removed.
■  Do not touch water pipes during and immediately after operation 
    as the pipes may be hot and could burn your hand. To avoid injury, 
    give the piping time to return to normal temperature or be sure to 
    wear protective gloves.
■  Do not touch any switch with wet fingers. Touching a switch with 
    wet fingers can cause electrical shock.
■  Before touching electrical parts, turn off all applicable power to 
    the unit.
(*) The models have a freeze prevention function that uses the heat 
pump  and  back  up  heater  to  keep  the  water  system  safe  from 
freezing in all  conditions.  If  there  is an  accidental  or  intentional 
power  shutdown,  using  glycol  is  recommended  (Refer  to  9.3 
Water pipework Caution: "Use of glycol”).    
2 ACCESSORIES
DANGER
WARNING
2
SHAPE
NAME
Outdoor unit installation &
owner’s manual(this book)
1
Water outlet connection pipe 
assembly
2
User interface kit(digital 
remote controller)
1
Tighten belt for customer 
wiring use
3
1
Wire control 
owner’s manual
1 1
1
1
Thermistor for domestic hot  
water tank or additional 
heating source*
1 1
2
3
11retlif epahs-Y
Transit line 
1 1
0
9.2.3 Main control board of 
hydraulic module .
Thermistor for backup heater
T1
1 0
3 SAFETY CONSIDERATIONS
The precautions listed here are divided into the following types.
They are quite important, so be sure to follow them carefully.
Meanings of DANGER, WARNING, CAUTION and NOTE symbols.
2.1 Accessories supplied with the unit
2.2 Accessories avaliable from supplier
SHAPENAME
water temperature thermistor
Transit line(for T1B)