EasyManua.ls Logo

Midea MSV1-09HRFN1-MT0W

Midea MSV1-09HRFN1-MT0W
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
For 18k and 24k models:
Compressor
on
off
on
on
on
off
off
off
4-way valve
Outdoor fan
Indoor fan
Indoor fan breeze(10s)
xx
no longer than 10m
Frequency F8
30s
10s
10s
Frequency F2
XX=90.
9.4.3.5 Evaporator coil temperature
protection
----T2> TEH2 , the compressor running
frequency decreases to the lower level and
runs for 20s.
When the frequency decreases to F2 and the
T2 is still over TEH2 for 3 minutes, the
compressor will stop.
----T2<48 or T2 stays in 48~ TEH2 for 6
minutes, the frequency will not be limited by T2.
----T2>60 , the compressor will stop and
restart when T2<48.
9.4.4 Auto-mode
This mode can be chosen with remote
controller and the setting temperature can be
changed between 17~30.
In auto mode, the machine will choose cooling,
heating or fan-only mode according to ΔT T
=T1-Ts).
ΔT=T1-Ts
Running mode
ΔT1
Cooling
-1<ΔT≤1
Fan-only
ΔT-1
Heating
Indoor fan will run at auto fan of the relevant
mode.
The louver operates same as in relevant mode.
If the machine switches mode between heating
and cooling, the compressor will keep stopping
for 15 minutes and then choose mode
according to T1-Ts.
If the setting temperature is modified, the
machine will choose running function again.
9.4.5 Drying mode
9.4.5.1 Indoor fan speed is fixed at breeze
and can’t be changed. The louver angle is the
same as in cooling mode.
9.4.5.2 Compressor running rules
2.0
1.5
1.0
F3
F2
F1
F1
2.5
0.5
0.0
9.4.5.3 Low indoor room temperature protection
In drying mode, if room temperature is lower
than 10, the compressor will stop and not
resume until room temperature exceeds 12.
9.4.5.4 Evaporator anti-freezing protection,
condenser high temperature protection and
outdoor unit frequency limit are active and the
same as that in cooling mode.
9.4.5.5 The outdoor fan operates the same as
in cooling mode.
9.4.6 Forced operation function
9.4.6.1 Enter forced operation function:
When the machine is off, pressing the touch
button will carry the machine to forced auto
mode. If pressing the button once again within
5 seconds, the machine will turn into forced
cooling mode.
In forced auto, forced cooling or any other
operation mode, pressing touch button will turn
off the machine.
9.4.6.2 In forced operation mode, all general

Related product manuals