Syn-Tech III P25 Portable Radio Alert Messages are given in Table 5-2:
Table 5-2: Syn-Tech III P25 Portable Radio Alert Messages
RADIO DISPLAY EXPLANATION
Battery Messages
BATTERY LOW!
PLEASE RECHARGE
If the battery voltage is below the first warning level, this message
appears once per minute.
BATTERY OUT WAITING FOR
RECHARGE
This alert is given if the battery is discharged and hasn't been
placed into the charger. If the battery is placed into the charger, but
charging hasn't started; "Please Wait" warning appears.
PLEASE TURN OFF!
DEEP DISCHARGE
If the battery is in deep discharge. The radio should be turned off.
BATTERY LOW
TX POWER OFF
It is displayed when the battery voltage is to low for transmission.
DISCHARGE BATTERY WITH
CHARGER
If the battery's deep discharge level has been reached; this
message appears on the display.
Warning messages
ZONE NOT PROGRAMMED
If an un-programmed zone is entered; this message appears in the
display.
NO TRANSMIT FREQUENCY
If the user attempts to transmit on the channel in which a
transmission frequency is not programmed; this message appears
in the display.
INVALID GROUP
If the user enters an invalid group number; this message appears in
the display.
INDEX FULL
If the user tries to add a record to an index that is full, this message
appears in the display.
CLONING FAILED,
No Connection
Established!
Check the cloning cable, and connections
CLONING FAILED
Unit is Not Cloneable
Radio must be programmed as cloneable.
CLONING FAILED
Clone ID Does Not
Match!
Clone ID of the radios must be same for cloning.
CLONING FAILED
Different WACN&SystemID!
WACN& System ID of the radios must be same for cloning.
CLONING FAILED
Different Software Type!