Completing a Charge Session
The charge session is complete when the proper amount of
charge is put back into the battery or the remaining estimated
time to charge counts down to zero.
If the GR8 nds that the battery is bad before the end of the
estimated time to charge, it displays the decision REPLACE
BATTERY or BAD CELL-REPLACE and the results.
If charging at the side posts or jump start posts and the test
data is inconclusive, the GR8 displays the decision JUMP
START POST or SIDE POST TEST. A JUMP START POST decision
prompts you to test at the battery. A SIDE POST TEST decision
prompts you to test using the side post adapters.
When the decision is GOOD BATTERY, the GR8 gives you
the option of topping o the batterys charge level before it
displays the results.
Diagnostic Charge Results
Use the UP or DOWN ARROW keys to scroll to each screen. To
return to the Main Menu, press the EXIT soft key. To print, press
the PRINT soft key.
Screen 1 of 3
Measured
voltage
Measured
capacity
Selected
rating
Replaced
AMP Hours
Battery
decision
Maximum
Charging Time
Screen 2 of 3
Replace
Range
OK-Replace Soon
Range
Good
Range
Screen 3 of 3
The GR8 displays one of three battery decisions (GOOD
BATTERY, REPLACE BATTERY, REPLACE-BAD CELL) and an
analysis, which includes the battery State-of-Health and State-
of-Charge.
Table 9: Battery Decisions: Diagnostic Charge
Battery Decision Recommended Action
GOOD BATTERY Return the battery to service.
OK-REPLACE SOON The battery may fail under extreme
climate conditions. The battery
result may also mean a poor
connection between the battery and
the vehicle and the battery. If you
tested the battery using the System
test, disconnect the battery cables
and retest using the Battery Test
before replacing it.
REPLACE BATTERY Before replacing the battery make
sure battery cables and connections
are clean and solid. If they are
loose or corroded, clean and tighten,
then retest.
BAD CELL - REPLACE Replace the battery. This decision
indicates a bad cell within the
battery.
WARNING: Charging a
battery with a bad cell is
dangerous!
24 VOLT BATTERY 24-volt battery detected. You are
attempting to test in-vehicle both
batteries in a 24-volt system.
Disconnect the batteries and test
them individually.
Chapter 6: Diagnostic Charging

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midtronics GR8-1250 and is the answer not in the manual?

Midtronics GR8-1250 Specifications

General IconGeneral
BrandMidtronics
ModelGR8-1250
CategoryDiagnostic Equipment
LanguageEnglish

Related product manuals