Operation (manual mode)
24
Switching power management on/off
You can deactivate Power
management.
T
his can, however, result in increased
electricity consumption.
Switch off the r
angehood. The
deflector plate must be retracted.
Remo
ve the grease filters.
The controls are accessible via the slots
for the gr
ease filters.
P
ress the run-on control 515 for
approx. 10 seconds, until the 1 lights
up.
The
n press in turn,
– the lighting control ,
– then the "" t
ouch control, and
– the lighting control again.
If power management is switched on,
the 1 and IS indicat
ors will light up
constantly.
If it is switched off, 1 and IS will flash.
P
ress "" to switch power
management off.
The 1 and IS indicat
ors will flash.
T
o switch it on, press "".
The 1 and IS indicat
ors will light up
constantly.
Co
nfirm the setting by pressing the
run-on control 5 15.
All the indicator lights will go out.
If you don't confirm your selection
within 4 min
utes, the rangehood will
automatically revert to the previous
setting.