Cleaning and care
37
Hook the panel in at the top and then
push it into position at the bottom.
Resetting the filter saturation
indicator for the grease filters
Once cleaning is complete, the filter
saturation indicator must be reset.
While the blower is turned on, touch
the grease filter control for approx.
3seconds, until only the 1 is flashing.
The grease filter symbol goes out.
When cleaning the grease filter before
the full operating time has elapsed:
Touch the grease filter control for
approx. 6seconds, until only the 1 is
flashing.
Replacing the grease filter
Regular usage and cleaning can cause
the filter surfaces to become worn.
If you identify any damage, replace the
grease filter.
Grease filters are available to order via
Miele Customer Service (see end of
these operating instructions for contact
details) or from your Miele dealer.