Installation
*INSTALLATION*
41
d
Air vent for recirculation mode. The distance to the ceiling or to cabinetry
installed above the appliance should be at least 11³/₄" (300mm).
Exhaust connection 6"(150mm)
Please observe installation positions for the socket and for the ducting outlet
shown on the relevant drawings when using the DADC6000 duct cover.
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop,
follow the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the “IMPORTANT SAFETY
INSTRUCTIONS” section.
Minimum distance S
Cooking appliance Miele
appliance
Non-Miele
appliance
Electric Cooktops 24" (610mm)
Electric Barbeques and Fryers 26" (660mm)
Multiburner Gas Cooktops
≤ 43,000 BTU/hr (12.6kW),
no burner > 15,000 BTU/hr (4.5 kW).
26" (660mm) 30" (760mm)
Multiburner Gas Cooktops
≤ 73,800 BTU/hr (21.6kW),
no burner > 16,500 BTU/hr (4.8 kW)
30" (760mm)
Multiburner Gas Cooktops
> 73,800 BTU/hr (21.6kW),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Not possible
Single Burner Gas Cooktops
≤ 20,500 BTU/hr (6 kW)
26" (660mm) 30" (760mm)
Single Burner Gas Cooktops
> 20,500 BTU/hr (6 kW)
≤ 27,600 BTU/hr (8.1 kW)
30" (760mm)
Single Burner Gas Cooktops
> 27,600 BTU/hr (8.1 kW)
Not possible