Technical Information
170
G 1xxx/G 2xxx
Options:
Function Programming Display
Software version ID check
Do not press the Delay
Start button. The "Delay
Start" LED is not lit.
"Rinse" LED is out or flashes. The
display shows the software version
ID no. in consecutive digits
(e.g., -1304).
Reset
Press the Delay Start
button 1x. The "Delay
Start" LED flashes 1x
rapidly intermittently.
Press the Start/Stop
button to reset all standard
settings.
The "Rinse" LED is out or flashes.
This programmable function can be
used to reset all modifiable
parameters to their standard
settings. The display shows p and a
digit alternately: p0 = Non-standard
settings have been made; p1 = All
settings reset to standard settings
or no modifications have been
made.
Water hardness setting
1
Press the Delay Start
button 2x. The "Delay
Start" LED flashes 2x
rapidly intermittently.
Press the Start/Stop
button as appropriate to
set the desired water
hardness.
The "Rinse" LED is out or flashes.
The display shows p and the digit/s
of the set value alternately.
Setting range: p1 to p70; see Table
080-9.
2
Dispensed rinse aid
quantity setting
Press the Delay Start
button 3x. The "Delay
Start" LED flashes 3x
rapidly intermittently.
Press the Start/Stop
button as appropriate to
make the desired setting.
The "Rinse" LED is out or flashes.
The display shows P and a digit
alternately: e.g., P3 (standard
setting) indicates a dispensed
quantity of 0.1 fl.oz. (3mL). Setting
range: 0 - 0.2 fl.oz. (0 - 6 mL). See
Table 080-10.
Adjust Sensor Wash
program
Press Delay Start 5x. The
"Delay Start" LED flashes
5x rapidly intermittently.
Press the Start/Stop
button to change the
setting.
The "Rinse" LED is out or flashes.
The display shows P and a digit
alternately. Setting options: P0 =
Standard program cycle (factory
setting); P1 = Adjusted program
cycle. The Sensor Wash program
can be adjusted in this parameter to
deal with stubborn soiling (or
otherwise low overall soiling). If this
option is selected, the main wash
temperature is increased to 131°F
and, as a result, the program
duration is extended.
Resetting standard
settings
Press Delay Start 12x.
The "Delay Start" LED
flashes 1x slowly and 2x
rapidly intermittently.
Press the Start/Stop
button to reset all settings
back to their factory
values.
The "Rinse" LED is out or flashes.
This programmable function can be
used to reset all customer-modified
parameters back to their standard
settings. The display shows P and a
digit alternately. P0 = Settings have
been modified; P1 = All settings reset
to standard settings or no
modifications have been made.