Setting the water hardness
level selector in the wash
cabinet
The water hardness selector is set at
setting 6 in the factory. It is only necess-
ary to reset the selector if water hard-
ness in your area measures between
650 and 1170 mg/l (36 - 65 °d German
scale, see chart).
°d mgl/l
water hardness
selector
(level)
1 - 35 20- 630 6*)
36 - 47 650- 850 4
48 - 65 860-1170 5
66 - 70 1190-1260 6*)
*) factory setting
For technical reasons do not set the
selector to setting 1 - 3.
Using a screwdriver remove the
cover from the water hardness selec-
tor.
Use a coin or screwdriver to adjust
the water hardness level selector in
the wash cabinet. There is a click as
each setting is reached.
Example:
The water hardness level is
680 mg/l. The water hardness level
selector must be set to setting 4,
650 - 850 mg/l (36 - 47 °d German
scale).
Fit the cover of the water hardness
selector back in place.
Water softener
18