Technical Information
92
G 600/G 800
3. Press and hold the Top solo button while turning the dishwasher on. Release
the Top solo button and immediately press it 2 more times. Flashing
Intake/Drain and Salt lights indicates successful accessing of Service Mode 2.
4. Turn the program selector switch to the appropriate position in Table 6-16 to
access the various functions of Service Mode 2. Press the Top solo button to
toggle functions on or off.
Selector switch position Function Options Start light status
1 o’clock Fault codes See Table 6-17 Flashing
2 o’clock Program index See Table 6-18 Flashing
4 o’clock EGS
On On
Off Off
5 o’clock Increase temperature
150°F Off
160°F On
6 o’clock Water softener
With Off
Without On
7 o’clock Increase water intake
On On
Off Off
8 o’clock 2 interim rinses
Without Off
With On
9 o’clock
Extended drying fan
time
Off Off
On On
10 o’clock Dishwasher width
24” Off
18” On
Table 6-16: G 811, G 851, G 851 Plus, G 856, G 856 Plus Service Mode 2 Functions
6.8.3.3.1 Accessing Fault Codes
1. Access Service Mode 2.
2. Turn the program selector switch to the 1 o’clock position. The Top solo light will flash.
3. Press the Top solo button once.
4. If the Top solo light is lit, no fault has been stored. If the light is not lit, turn the selector
switch slowly clockwise until the Top solo light lights up.
5. Use the fault chart (Table 6-17) to determine which fault has been stored in the dishwasher.
6. Turn the dishwasher off.
Selector switch position Fault code Fault
1 o’clock F00 No error
2 o’clock F01 NTC or NTC connections open-circuited
3 o’clock F02 NTC or NTC connections short-circuited
4 o’clock F03
Electronic failure, selector switch position not
found
5 o’clock F04
Heating failure - heating circuit opened or
defective electrical component in heating circuit
6 o’clock F05 Water drainage failure, heater level switch
7 o’clock F06
Too few pulses at flow meter / start of water
intake
8 o’clock F07
Too few pulses at flow meter / end of water
intake
9 o’clock F08 Water intake failure, heater level switch
10 o’clock F09
Heater level switch not switching on at the end
of thermal stops
Table 6-17: G 811, G 851, G 851 Plus, G 856, G 856 Plus Fault Code Chart