Electrical connection
89
Data plate
The silver data plate is located along
the front side of the oven with the door
open (see "Guide to the oven").
Before connecting the appliance
to the power supply, make sure that
the voltage and frequency listed on
the data plate correspond with the
household electrical supply. This
data must correspond to prevent
machine damage. Consult an
electrician if in doubt.
H2265B
Electrical connection 208V
Do not connect the oven to a
240V power supply.
The oven is equipped with a 6'
3" (1.9m) long flexible power cord with
a NEMA 14-30P plug, ready for
connection to a 120/208V, 60Hz, 20A
power supply.
Maximum connected load: 3,600W
Electrical connection 240V
The oven is equipped with a 6'
3" (1.9m) long flexible power cord with
a NEMA 14-30P plug, ready for
connection to a 120/240V, 60Hz, 20A
power supply.
Maximum connected load: 3,800W
H2265E
Electrical connection 208V
Do not connect the oven to a
240V power supply.
The oven is equipped with a 6'
3" (1.9m) long flexible power cord with
a NEMA 14-50P plug, ready for
connection to a 120/208V, 60Hz, 40A
power supply.
Maximum connected load: 9,700W, in
combination with Miele cooktop
KM6002.
Electrical connection 240V
The oven is equipped with a 6'
3" (1.9m) long flexible power cord with
a NEMA 14-50P plug, ready for
connection to a 120/240V, 60Hz, 40A
power supply.
Maximum connected load: 9,900W, in
combination with Miele cooktop
KM6002.
SAVE THESE INSTRUCTIONS FOR
THE ELECTRICAL INSPECTOR'S
USE.