21
TECHNICAL DATA
Power source: TIG 400 AC/DC TIG 500 DC TIG 500 AC/DC
Mains voltage / Fuse
Mains voltage / Fuse
(changeable)
Consumption max.
Efficiency
Current range DC
Current range AC
Duty cycle 100%
Duty cycle 60%
Duty cycle 35%
Open circuit voltage DC
1
Sphere of application
2
Protection class
Standard
3x400 V / 25 A
-
3x400 V / 25 A
3x440 V / 20 A
3x500 V / 20 A
23,2 KVA
0.85
5 - 400 A
5 - 400 A
300 A
355 A
400 A
85 V
S
IP 21
EN60974-1
EN50199
3x400 V / 35 A
26,8 KVA
0.85
10 - 500 A
-
400 A
500 A
-
85 V
S
IP 21
EN60974-1
EN50199
3x400 V / 35 A
27,5 KVA
0.85
10 - 500 A
10 - 500 A
400 A
500 A
-
85 V
S
IP 21
EN60974-1
EN50199
Control:
Anti-stick
Pilot arc
Arc power
Hot-start
Pulse time
Pause time
Base current
Gas pre-flow
Gas post-flow
Slope up
Slope down
Reduced current
AC-t-balance, based on time (TIG)
AC-I-balance
based on current intensity (TIG)
AC frequency (TIG)
AC frequency (MMA)
Starting current
Stop current
Spot welding time
Box 1
5 A
4 %, min. 5 A
0 - 150 %
0 - 100 %
0,01 - 10 secs
0,01 - 10 secs
1 - 99 %, min. 5 A
0 - 10 secs
3 - 20 secs
0 - 10 secs
0 - 10 secs
0 - 100 %, min 5 A
1 – 100 %
1 - 100%, min 5 A
1 - 300 Hz
1 - 100 Hz
0 – 100 %, min. 5 A
0 – 100 %, min. 5 A
0.1 - 50 secs
Box 2
5 A
4 %, min. 5 A
fixed
0 - 100 %
-
-
-
0.2 sec. (fixed)
0 - 30 secs
-
0 - 10 secs
-
0 – 100 %
-
10 – 500 Hz
-
-
-
-
Dimensions and weight:
Dimensions
Weight
Weight, changeable
700x550x1050
149 kg
179 kg
700x550x1050
157 kg
700x550x1050
173 kg
1
S
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock
2
Indicates that the machine cannot be used outside in the rain

Related product manuals