INSTALLATION
12 TECHNICAL DOCUMENTATION
REGULATIONS
The appliance should be installed by a competent installer in accordance with the applicable national and
local standards, rules and regulations (please refer to pages 06 and 07 for safety guidelines).
INSTALLATION AREA
MOUNTING - SOLID WALLS (BRICK OR BLOCK)
Fix the mounting bracket with suitable fixings using a spirit level and ensuring that there is sufficient clearance
around the boiler to allow for access and flue installation.
MOUNTING - NON-LOAD BEARING WALLS (STUDDING OR LIGHTWEIGHT PARTITIONS)
We recommend the use of a purpose designed mounting frame which is available from Mikrofill Systems Ltd.
or alternatively we can supply drawings for site construction of the same.
INSTALLATION GUIDELINES
The following guidelines should be complied with;
The recommended minimum clearances are as follows:
• 750mm to the front (to allow free space for movement).
• 400mm above.
250mm below.
25mm at the sides.
Due to the low noise level, there should be no need for additional sound insulation of the room.
Due to its compact design, very little installation space is required (see clearance dimensions
below).
The location options for the boiler are increased because it is suitable for both open flued and room
sealed operation.
The device should be installed in a frost free room due to the risk of freezing of the condensate drain.
The built-in protection system is activated when the temperature of the central heating water falls
below 5°C.
Ensure that there is sufficient room around the device for maintenance and the replacement of
components if necessary.