EasyManuals Logo

Miller Multimatic 235 User Manual

Miller Multimatic 235
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
OM-283935 Page 58
10-16.Common GMAW (MIG) Shielding Gases
This is a general chart for common gases and where they are used. Many different combinations (mixtures) of shielding gases have been developed
over the years. The most commonly used shielding gases are listed in the following table.
Application
Gas
Spray Arc
Steel
Short
Circuiting
Steel
GMAW-P
Steel
Spray Arc
Stainless
Steel
Short
Circuiting
Stainless
Steel
GMAW-P
Stainless
Steel
Spray Arc
Aluminum
Short
Circuiting
Aluminum
GMAW-P
Aluminum
Argon
All
Positions
All
Positions
All
Positions
All
Positions
Argon + 1% O
2
Flat &
Horizontal
Fillet
All
Positions
Flat &
Horizontal
Fillet
Argon + 2% O
2
Flat &
Horizontal
Fillet
All
Positions
Flat &
Horizontal
Fillet
Argon + 5%
CO
2
Flat &
Horizontal
Fillet
All
Positions
Argon + 10%
CO
2
Flat &
Horizontal
Fillet
All
Positions
All
Positions
Argon + 25%
CO
2
All
Positions
Argon + 50%
CO
2
All
Positions
CO
2
All
Positions
Helium
All
Positions
1
Argon +
Helium
All
Positions
1
90% HE +
7-1/2% AR +
2-1/2% CO
2
All
Positions
65% AR + 33%
HE + 2% CO
2
All
Positions
1 Heavy Thicknesses

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miller Multimatic 235 and is the answer not in the manual?

Miller Multimatic 235 Specifications

General IconGeneral
Input Voltage120/240 V
Input Hz50 / 60 Hz
Max Output235 A
Welding ProcessesMIG, Stick, TIG, Flux-Cored
Wire Feed Speed Range50-700 IPM
Wire Size Range (Flux-Cored)0.030-0.045 in (0.8-1.2 mm)
Input PhaseSingle Phase
Wire Size Range (MIG)0.024 - 0.035 in