Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
Table 8: Mechanisms and Settings
Make sure mechanisms are serviceable and settings are correct to prevent unsatisfactory
performance.
Mark
1
2
3
4
5
6
Do this each
Component
More Data
x
2400 hours
controller circuitry
Examine wiring and connections in electrical
boxes. Look for corrosion, loose connections.
See Section 3.1.3
x
200 hours
water pressure regulator for
optional supply injector
See Figure 10. Value: 28 PSI (193 kPa).
x
200 hours
compressed air mechanisms
See Supplement 2, Figure 14
x
200 hours
bath level sensor that uses air
pressure
Examine the air tube and connections. See
Figure 11
x
600 hours
push-down system that uses
compressed air
Look at the shell when the machine operates
to make sure there is no irregular movement
of the shell. See Supplement 4
x
600 hours
door seal system that uses
compressed air
Look at the doors when the machine operates
to make sure there is no evidence of a door
leak. See Supplement 3
26