Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
Table 7: Motor Grease Schedule. Use the data in Section 3.1.4.2 to complete this table.
Interval
Quantity
Dates When Grease is Added
Motor Identification
(example: main drive)
Years
Hours
fl oz
mL
.
Table 8: Mechanisms and Settings
Make sure mechanisms are serviceable and settings are correct to prevent unsatisfactory
performance.
Mark
1
2
3
4
5
6
Do this each
Component
More Data
x
2400 hours
controller circuitry
Examine wiring and connections in electrical
boxes. Look for corrosion, loose connections.
See Section 3.1.3
x
200 hours
water pressure regulator for
chemical flush
See Figure 14. Value: 28 PSI (193 kPa).
x
600 hours
conductivity sensors, if
supplied
x
200 hours
ph sensors, if supplied.
Do the calibration procedure as told in the
manufacturer manual supplied with the
machine.
x
200 hours
compressed air mechanisms
See Supplement 4, Figure 17
x
40 to 60 hours
chain mist oiler system
See Figure 23. Examine chains for oil. Make
sure that each nozzle gives a spray each time
that the tunnel does a transfer. If not, remove
contamination and make sure that the air
pressure gauge shows the correct pressure for
the number of chains. Values are given in
pounds per square inch and (kilopascals):
1 chain = 20 (138)
2 chains = 35 (241),
4 chains = 40 (276),
6 chains = 45 (310),
8 chains = 50 (345),
10 or more chains = 60 (414).
32