Milwaukee LDM 30 - Technical Data; Error Code Table; Specified Conditions of Use

Milwaukee LDM 30
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2ENGLISH
TECHNICAL DATA
Receiving Lens 15 mm x 9.5 mm
Measuring Range
Minimum distance
0.15 m
Maximum distance 30 m
Distance Measurement
Typical tolerance
(applies for 100 % target reectivity (white painted wall), low
background illumination, 25 ºC)
± 2.0 mm
(an addidional tolerance of 0.1 mm/m should be taken into account)
Maximum tolerance
(applies to targets with lower reectivity, high background
illumination, or temperatures approaching the lower/upper
limit)
± 4.0 mm
(an addidional tolerance of 0.15 mm/m should be taken into account)
Smallest unit displayed 1.0 mm
Laser Spot Size
10 m distance: 20 x 35 mm
30 m distance: 40 x 65 mm
Laser Class 2
Laser Type 650 nm, < 1 mW
Laser Radiation
Vertical Angle ± 1 degree
Horizontal Angle + 1 degree
Display Type LCD (25 mm x 25 mm)
Laser auto off time 90 sec
Device auto off time 180 sec
Power Type AAA 2x (Alkaline Battery)
Battery Life 10000 (Single Measure)
Operating Temperature Range 0°C to +40°C
Storage Temperature Range
-10°C to +60°C
Weight without Battery 72 g
Dust and Water resistance IP54
SPECIFIED CONDITIONS OF USE
The laser distance measurer can be used for measuring distances
Do not use this product in any other way as stated for normal use.
ERROR CODE TABLE
Code Description Solution
Err500 Hardware problems Turn the meter off and back on. If the
problem remains, return the meter to
the nearest service center.