6-12
8
Press the key and fill up the cap with
cleaning solution for maintenance.
When you press the key, cleaning solution drips
into the cap.
When you press the key again, the solution stops
dripping.
Repeat the drops several times to fill the cap with the cleaning
solution just before the solution overflows from the cap.
9
Press the key.
10
Press to set the time for the cleaning
solution to be left as it is.
Set value: 1 to 99 min (by the unit of 1 min)
11
Press the key.
The cleaning solution in the cap is absorbed.
The screen on the right is displayed for the time set in Step 10.
When the set time has elapsed, the screen returns to LOCAL.
When nozzle missing is not corrected even after this cleaning has been performed several times,
perform "When Nozzle Clogging Cannot Be Solved" ( P.6-18) and "DISCHARGE & WASH" ( P.6-
19). When the problem is not solved even after the operation above, contact the distributor in your
region or our service office.
When this machine is not filled with cleaning solution for maintenance, do the following:
(1) Perform the operations in Steps 1 to 5.
(2) Fill up the cap with cleaning solution for maintenance, using a syringe.
(3) Perform the operations in Step 9 and later.
The waste ink discharged by head nozzle cleaning is not counted as the waste ink automatically
accumulated in this device ( P.6-37). Check the status of the waste ink tank without fail before/after
the cleaning.