2-30
Setting the Torque Limiter
The take-up device is provided with a torque limiter. The take-up torque can be adjusted with the torque limiter.
(The torque limiter is set at the maximum value when shipped from the factory.)
In the following cases, make the adjustment:
(1) when the tension is too strong in using thin medium
(2) when performing combined operation of print & cut
A clockwise turn : Increases torque (a heavy and thicker medium such as tarpaulin or the like)
A counterclockwise turn : Decreases torque (for light medium)
When not using taking-up device
When the torque limiter is adjusted too weak:
The medium cannot be taken up firmly.
When the torque limiter is adjusted too strong:
Slack may occur depending on the medium and have an influence on the image quality.
In addition, when performing combined operation of print & cut and when making the medium return to
the cutting start position, it may not return to the origin of the resister mark after printing is completed.
When performing printing or cutting of 700 mm or more
without using the taking-up device, evacuate the taking-
up device to right and left. The quality of the print and cut
may become low because of the impact when the front
end of the medium touches the taking-up device. (Same
as when fixing the optional dry evacuation unit)
50% of the maximum torque 100% of the maximum torque
Torque indicator
Adjustment nut