Chapter5 Troubleshooting
5-12
SYSTEM HALT
The NCU sensor sensitivity is falling.
Replacement of the NCU is recommended.
Contact our service desk or your local dis-
tributor to call for service.
The thermistor connection of a heater is
defective.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The temperature abnormality of the
heater has been detected.
When this error occurred and if the tem-
perature abnormality cannot be
resolved, the power supply of the
machine is forcibly turned off.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Due to a certain error, the function can-
not be performed.
Return to the local screen, check the error
status and take a countermeasure.
There remains received data that has
not yet been printed.
Execute the data clear function. ( P.2-14)
An error occurred in the mounted heads.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
The media width or the media length
required for printing is not enough.
Change the media to the one with enough
width or length.
When the media width narrows because the
origin moved, slide the origin to the right to
widen the effective media width.
An error occurred in the main PCB
FROM.
Turn off the main power to the machine and
turn it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Message Solution
Turn off the main power to the machine and turn it on after a while.
If the same error message appears again, check the number and contact your local dis-
tributor to call for service. (“000” is the error No.)
Perform cleaning around the wiper.
Turn off the main power to the machine and turn it on after a while.
If the same error message appears again, check the number and contact your local dis-
tributor to call for service.
Message Cause Solution
ERROR 658
NCU SENSOR LV LOW
ERROR 702
THERMISTOR CONNECT
ERROR 710
HEATER TEMP ERROR
ERROR 901
INVAILD OPERATION
ERROR 902
DATA REMAIN
ERROR 90d
NO HEAD SELECT
ERROR 90f
PRINT AREA SHORT
ERROR 04
PARAM ROM
SYSTEM HALT (*)
000 : MESSAGE
SYSTEM HALT (*)
406 : WIPER ORG

Table of Contents