Important:
Water-based transportation liquid
(S-46), supplied in the head at the
time of shipment, reacts to solvent ink
and may cause clogging. Therefore,
it is necessary to wash the new head
before proceding with installation.
2-3. Insert hex screws in holes at front and
rear of Head Adjusting Plate.
2-4. Before installing new Head inspect the
area where Head will sit for any debris such
as dried ink. Clean with Solvent (SPC-0336)
if neccessary.
2-5. Grasping damper projection, place
Head in position. Install, but do not tighten
the front and rear hex screws.
2-2. Fill syringe with 6-8 cc of S-Head
Replacement Solution. Inject approx 3-4 cc
into each Damper Insertion Projection over
a period of about 30 seconds. Head can be
damaged if fl uid is injected too fast.
2. Installation of New Head:
© 2005 Mimaki USA Pg. 3/7
2-1. Unpackage new head. Copy down the
new Head ID exactly as it appears on head.
1-9. Head and Adjusting Spring removed.
If head is covered by warranty, fl ush, drain,
place rubber cap over nozzles and package
ready for return to Mimaki USA.