10
10. Replace or clean when it is dirty
(1) Replace the CP pad set.
Replace CP pad set (SPA-0257) when it is dirty.
1
Push up the tabs (2places) of CP pad
Assy.
2
Remove the CP pad Assy.
3
Attach a new CP pad Assy.
After inserting the tabs of CP pad Assy to the slit
of C slider, fit the whole.
CP pad Assy
CP pad Assy
Tabs
C Slider