EasyManua.ls Logo

Minelab F3Ci User Manual

Minelab F3Ci
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
F3Ci
Revision 01
Part No: 4901-0144
OPERATIONS MANUAL

Other manuals for Minelab F3Ci

Questions and Answers:

Minelab F3Ci Specifications

General IconGeneral
BrandMinelab
ModelF3Ci
CategoryMetal Detector
LanguageEnglish

Summary

Introduction

General Description and Preparation

Mine Detecting Set

Lists components included in the F3Ci mine detecting set, including cases and accessories.

F3Ci Main Components

Identifies and describes the main physical components of the F3Ci metal detector.

F3Ci Preparation

Step-by-step instructions for preparing the F3Ci detector for use, including battery insertion.

Functional Description

Functional Controls and Displays

Describes the location and function of controls and displays on the F3Ci handle assembly and main body.

On/Off Knob Operation

Explains how to switch the F3Ci detector on and off, and the start-up sequence.

Sensitivity Knob Settings

Details the seven preset sensitivity settings and their effects on detection.

Ground Balance Procedure

Explains how to perform the ground balancing sequence to remove soil effects.

Noise Cancel Function

Describes how to use the Noise Cancel button to minimize electrical interference.

Mode Select Button Functions

Explains the three modes: Detection, Interrogation, and Pinpoint.

LED Display Indicators

Describes the nine-LED display and how it indicates target size and proximity.

Battery Status Check

How to check the battery status using a button combination.

Earset Socket Connection

Explains the earset connection and its purpose for audio output.

Functional Tones Explained

Explains the different tones emitted by the detector for various events and conditions.

Test Piece Functional Test

Instructions for using the Test Piece to verify the detector's operational capability.

Operating Procedures

Operating Procedures Introduction

Introduces the chapter on safe and effective operation of the F3Ci detector.

Standard Operating Procedure

Outlines the three-step standard procedure for operating the F3Ci detector.

STEP 1 Switch ON

Details the first step of turning the F3Ci detector on and initial checks.

STEP 2 Ground Balance

Explains the procedure for performing ground balance on the F3Ci detector.

STEP 3 Test Piece

Details the third step of using the Test Piece to confirm detector functionality.

Optional Procedures Overview

Describes optional procedures for enhancing detector performance and features.

Noise Cancel Procedure

Describes the optional Noise Cancel procedure to mitigate interference.

Activate/Deactivate LEDs

How to activate or deactivate the LED display on the F3Ci detector.

Activate/Deactivate Vibration

How to activate or deactivate the vibration feature on the F3Ci detector.

Sweeping Procedure

STEP 1 Mapping the Target

Describes the first step in target detection: mapping the area using edge detection.

STEP 2 Pinpointing the Target

Details the procedure for pinpointing the exact center of a detected target.

STEP 3 Interrogating the Target (Optional)

Optional step for analyzing targets by identifying their characteristics using different tones.

Multiple Targets Handling

STEP 1 Mapping Multiple Targets

How to map an area containing multiple potential targets.

STEP 2 Pinpointing Multiple Targets

Procedure for pinpointing the location of multiple individual targets.

STEP 3 Interrogating Multiple Targets (Optional)

Optional step to analyze characteristics of multiple targets with different tones.

Operating Multiple Detectors

Completion of Operations

Care and Troubleshooting

Routine Care Guidelines

Guidelines for proper daily care and cleaning of the F3Ci detector.

Troubleshooting Common Problems

A table listing common problems and their recommended solutions for the F3Ci detector.

Technical Specifications

Related product manuals