TROUBLESHOOTING
94
PROBLEM
No display in the data
panel when the
camera is switched
on.
-- appears in the data
panel's aperture
display.
HELP displayed in the
bodt data panel.
Autofocus does not
work or the lens does
not focus when the
shutter-release
button is pressed.
Camera cannot be
shifted out of P mode.
Card system does not
function.
Eye-Start does not
work.
CAUSE
Battery exhausted.
Battery not installed
correctly.
Lens not attached
correctly.
Contacts on camera
and/or lens are dirty.
AZ/MZ switch set to
MZ.
Winding motor
problem.
Camera set to manual
focus.
AZ/MZ switch set to
MZ.
Lens is not attached
correctly.
Subject difficult to
autofocus.
Creative Expansion
Card in use.
Card not installed
correctly.
Grip Sensor is not
activated.
SOLUTION
Install a fresh battery
Remove the battery
and install it correctly.
Attach the lens so that
it locks in place with a
click.
Clean contacts with a
dry, clean cloth.
Move the AZ/MZ
switch AZ.
Remove the battery,
then reinstall it.
Set the camera to
autofocus mode.
Turn the AZ/MZ
switch AZ.
Attach the lens so that
it locks in place with a
click.
Focus manually.
Use the card key to
switch the card off.
Remove and reinsert
the card correctly.
Touch the Grip
Sensor