Unable to
select a cool
enough
temperature.
Due to a rise in the stored
water temperature, the
power rating may be too
high.
Turn the TOP knob to
MEDIUM setting and
re-adjust temperature
k n o b u n t i l s u i t a b l e
temperature is achieved.
H a ndset s p r aypla t e
blocked.
Remove and clean.
Shower
cycles from
hot to cold.
Temperature knob or
heater setting too high.
Turn the TOP knob to
MEDIUM setting and
re-adjust temperature
k n o b u n t i l s u i t a b l e
temperature is achieved.
Fault Diagnosis
Symptom Probable Cause Possible Remedy
Elite ST fails
to operate.
Electrical supply isolated
at double pole switch.
Switc h on e le ctric al
supply via pullcord or
wall mounted switch.
Incoming water supply
isolating valve turned
down or off.
Turn isolating valve to
fully on position.
No water
or very low
ow rate.
H o s e o r h a n d s e t
sprayplate blocked.
Remove and clean.
Fuse blown or MCB/RCD
tripped indicating possible
electrical fault.
Renew the fuse or reset
the MCB/RCD. If fault
persists, contact your
installer.
The trouble shooting information below gives details on probable causes and remedies should difculties
be encountered whilst the shower is in operation.
Warning! There are no user serviceable components beneath the cover of the appliance.
ONLY A COMPETENT TRADESPERSON SHOULD REMOVE THE FRONT COVER!
Power
Light
Low
Flow
Light
Heater Setting
Low / Medium
/ High
AnyOFF OFF
AnyOFF OFF
AnyON ON
AnyON ON
Medium / HighON OFF
HighON OFF
Medium / HighON ON