Operation and Maintenance
Event message Trigger condition
Details
63
Severity
Not enough licences
for integrated mobile/
external phones
The connection setup with an
integrated mobile/external phone
has failed because the number
of configured mobile/external
phones is greater than the number
of licences available. All the
integrated mobile/external phones
remain blocked until a sufficient
number of licences are available.
Number of
licences, number
of configured
mobile/external
phones, date, time
Serious (negative,
with match)
NTP: Time
synchronisation failed
Time synchronization via the NTP
server (NTP = Network Time
Protocol) has failed.
Date, time Serious (negative,
with match)
NTP: Time
synchronisation re-
established
Time synchronization via the NTP
server (NTP = Network Time
Protocol) has been restored.
Date, time Serious (positive,
with match)
Outgoing call rejected Call rejected by the network
• On any line: error code 34
• On required line group: error
code 44
Port number of
the exchange line
circuit, cause,
date, time
Normal (without
match)
Overheat (Mitel SMBC
only)
The temperature inside the
communication server is too high.
The appropriate measures must
be taken immediately to improve
the heat dissipation, e.g. by
providing the required clearances,
lowering the ambient temperature
or installing the fan from the rack-
mounting set (Mitel 430 only).
Card number,
temperature, date,
time
Critical (negative,
with match)
63
The node is also always indicated in an AIN.
Release 7.1
System Manual for Mitel SMB Controller 238