Operation and Maintenance
Event message Trigger condition
Details
63
Severity
No configuration
template
A configuration template for a
Mitel SIP terminal is missing in
the communication server file
system. Without the configuration
template, no configuration file can
be generated for this terminal type.
No configuration
template, date,
time
Serious (negative,
with match)
No DECT DSP
channels available
DECT channels on DSP-0x
overloaded
Date, time Normal (without
match)
No DTMF receiver
available for integrated
mobile/external
phones
A permanent DTMF receiver (for
detection suffix dialling function
codes) could not be assigned to an
integrated mobile/external phone
with enhanced functionality.
BCS Ref., date,
time
Serious (without
match)
No other system
clone detected (Virtual
Appliance only)
The clone detection service on the
licence server (SLS cloud) could
not find any other clone (system
with the same EID) for a long time
(24 hours).
Date, time critical (positive,
with match)
No response from
network
No answer to Call Setup on BRI-T/
PRI interface
Port number of
the exchange line
circuit, date, time
Normal (without
match)
No response from user No answer to incoming DDI call
from user on S bus or DSI
DDI No., date,
time
Normal (without
match)
Node: Connection lost A node is not connected to the
Master for a certain amount of time
(configurable).
Node number,
date, time
critical (negative,
with match)
Node: Connection re-
established
A node is reconnected with the
Master for a certain amount of time
(configurable) after an interruption.
Node number,
date, time
critical (positive,
with match)
63
The node is also always indicated in an AIN.
Release 7.1
237 System Manual for Mitel SMB Controller