Operation and Maintenance
Event message Trigger condition
Details
63
Severity
Remote maintenance
disabled
Remote maintenance has been
deactivated
Date, time Normal (positive,
with match)
Remote maintenance
enabled
The remote maintenance has been
activated (The report is output
unfiltered on local destinations).
Date, time Normal (negative,
with match)
Restart of applications
card CPU2 executed
The restart of applications card
CPU2 was executed successfully.
Date, time critical (positive,
with match)
Restart of applications
card CPU2 required
The system has detected that a
manual restart of the applications
card CPU2 is required (e. g. for a
security update).
Date, time critical (negative,
with match)
Restricted operating
mode disabled
Restricted mode could be disabled
again.
Date, time critical (positive,
with match)
Restricted operating
mode enabled (not
valid for Virtual
Appliance)
The communication server has
switched to restricted mode.
Cause: 0: No valid licence
Cause, date, time critical (negative,
with match)
Restricted operating
mode enabled (Virtual
Appliance only)
The communication server has
switched to restricted mode.
Cause: 0: No valid licence. 1:
Link to gateway satellite lost.
2: Max. duration without link to
licence server reached. 3: Your
system clone confirmed. 4: Licence
check mode mismatch in SLS and
MiVoice Office 400. 5: Support
mode enabled.
Cause, date, time critical (negative,
with match)
Satellites missing after
supervision time
After an AIN update (Master and all
satellites) some satellites no longer
have a connection to the Master.
Total satellites
missing, Satellites
rolled back, Date,
Time
Serious (without
match)
63
The node is also always indicated in an AIN.
Release 7.1
241 System Manual for Mitel SMB Controller