EasyManua.ls Logo

Mitsubishi Electric FX5U - Appendix 4 SD Memory Card

Mitsubishi Electric FX5U
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX
Appendix 3 I/O Module
139
A
Powered input/output module
External dimensions
Part names
Model W: mm (inches)
FX5-32ER/ES, FX5-32ET/ES, FX5-32ET/ESS 150 (5.91")
No. Name Description
[1] Extension connector cover (for preceding module) Cover for protecting the extension connector cover (for preceding module).
[2] Terminal block cover Cover for protecting the terminal block.
The cover can be opened for wiring. Keep the covers closed while equipment is running
(power is on).
[3] POWER LED Indicates whether the powered input/output module is powered or not.
Lit: Powered
Off: Not powered or hardware error
[4] Input display LED Lit when input is on.
[5] Output display LED Lit when output is on.
[6] Extension connector cover (for next module) Cover for protecting the extension connector cover (for next module).
[7] Extension connector (for preceding module) Connecter for connecting the supplied extension cable that connects to the preceding
module (the CPU module side).
[8] Terminal block mounting screws Gradually loosen the left and right screws (alternatingly) to remove the upper part of the
terminal block.
[9] Terminal Terminals for power, input, and output.
For details on the terminal layout, refer to Page 140 Terminal layout.
[10] Extension connector (for next module) Connector for connecting the extension cable of an extension module.
140 (5.52")
(mounting hole pitch)
(mounting hole pitch)
80
(3.15")
90
(3.55")
W83
(3.27")
8
(0.32")
2-
4.5 mounting holes
[Without cover]
Unit: mm (inches)
[10]
[1]
[7]
[2]
[8] [9] [8]
[8] [9] [8]
[4] [5] [6][3]

Table of Contents

Related product manuals