Learning to Use the FX Family for Positioning Control FX2N-10GM and FX2N-20GM positioning
4 - 58
MITSUBISHI ELECTRIC
Open the
Parameter Machine Zero
window by selecting
Parameters
Positioning
Machine Zero
from the menu bar at the top of the screen.
Since mechanical hardware will not be connected to the FX
2N
-20GM for this example, it is not nec-
essary to configure the limit switch and DOG switch settings in the parameters. It is, however, nec-
essary to reduce the
Creep speed
and the
Zero return speed
.
For the last parameter screen, open the
Parameter Settings
window by selecting
Parameters
Positioning
Settings
from the menu bar at the top of the screen.
None of the parameters in the
Parameter Settings
window need to be changed. When using a
mechanical plotter, however, these settings become more important.
Fig. 4-39: Parameter Machine Zero
window
Fig. 4-40: Parameter Settings
window
452060da.eps
Specify the same settings
for the Y-axis
452070da.eps
NO CHANGES

Table of Contents