100
APPX
Appendix 1 Instruction Replacement List
Instruction Replacement List of ST Programs
Replaced instructions
The following instructions will be replaced to GX Works3 compatible instructions when converting the project.
FX3 Series MELSEC iQ-F Remarks
OUT_T OUT_T, OUTH, OUTHS
When the timer is 1 ms, it will be
replaced to the OUTHS instruction.
When the timer is 10 ms, it will be
replaced to the OUTH instruction.
When the timer is 100 ms, it will be
replaced to the OUT_T instruction.
When a label is used instead of a
timer device, the instructions will not
be replaced.
*1
SQRP SQRTP
DSQR DSQRT
DSQRP DSQRTP
SER SERMM
SERP SERMMP
DSER DSERMM
DSERP DSERMMP
RAMP RAMPF
SORT SORTTBL
HEX HEXA
HEXP HEXAP
SORT2 SORTTBL2
DSORT2 DSORTTBL2
HOUR HOURM
DHOUR DHOURM
IVCK IVCK SM4095 is added to parameters of
instructions. Change to an
appropriate device or label.
IVDR IVDR
IVRD IVRD
IVWR IVWR
IVBWR IVBWR
IVMC IVMC
ADPRW ADPRW
LOADR ERREAD
*2
LOADRP ERREAD
*2
RWER ERWRITE
*2
RWERP ERWRITE
*2
INITER ERINIT
*2
INITERP ERINIT
*2
SQR SQRT_E These instructions will be converted
to standard functions.
LEN LEN_E
RIGHT RIGHT_E
LEFT LEFT_E
LIMIT LIMIT_E
DLIMIT LIMIT_E
BOOL_TO_STR BOOL_TO_STRING
BOOL_TO_STR_E BOOL_TO_STRING_E
INT_TO_STR INT_TO_STRING
INT_TO_STR_E INT_TO_STRING_E
DINT_TO_STR DINT_TO_STRING
DINT_TO_STR_E DINT_TO_STRING_E
REAL_TO_STR REAL_TO_STRING
REAL_TO_STR_E REAL_TO_STRING_E
STR_TO_BOOL STRING_TO_BOOL