148
1 FUNCTIONS
1.12 Web Server Function
*1 When the device name is not displayed (devNamDisp = 0), no error occurs without this setting.
Precautions
Write all the necessary parameters. If the necessary parameters are not written or the setting value is out of range, an error
occurs.
If the data format is the single-precision real number or double-precision real number, the positional notation will be the
decimal.
dev[31].format The data format of the device 32 0: 16-bit signed
1: 16-bit unsigned
2: 32-bit signed
3: 32-bit unsigned
4: Single-precision real number
5: Double-precision real number
6: Bit
direction Display direction 0: Vertical
1: Horizontal
(If omitted, it is
0.)
blkSize Block size 1 to 32
(The number of lines is displayed when the display direction is
set to vertical, and the number of columns is displayed when the
display direction is set to horizontal.)
devNamDisp Device name display 0: Not display
1: Display
(If omitted, it is
1.)
devNamCol Character color of device name The RGB value or color name
Example: #FF0000 (RGB value) or red (color name)
devNamBkCol Background color of device name
devNamWidth Cell width of device name Positive real numbers (unit: px)
(For the horizontal display direction, the setting value of the cell
width of device value takes priority, and for the vertical display
direction, the setting value of the cell height of device value
does.)
*1
devNamHeight Cell height of device name
devValCol Character color of device value The RGB value or color name
devValBkCol Background color of device value
devValWidth Cell width of device value Positive real numbers (unit: px)
devValHeight Cell height of device value
InCol Line color The RGB value or color name
xPos X-coordinate The horizontal coordinate of the data block at the upper left end
(unit: px)
yPos Y-coordinate The vertical coordinate of the data block at the upper left end
(unit: px)
Parameter Item Description Requirement