CHAPTER6 FUNCTIONS
1
2
3
4
5
6
7
8
6.17 Self-diagnostic Function
6 - 103
: Self-diagnostics is performed. : Self-diagnostics is not performed
*1: The operating status can be changed to "Continue" with the parameter setting of GX DeveloperÅiThe default is set to "Stop").
*2:This option can be set "not checked" (set "checked" by default) with the parameter setting of GX Developer. Also, this option is not checked
while SM251 is on.
*3: This option can be set "not checked" (set "checked" by default) with the parameter setting of GX Developer.
*4: This error includes an operation error when device range check is made at index modification.
*5: The CPU module having the serial number (first five digits) is "10042" or later can be diagnosed.
Table6.29 Self-diagnostics list (continued)
Diagnostics
Error message Diagnostic timing
CPU
module
status
LED status
Q00UJ
CPU
Q00U
CPU,
Q01U
CPU
Q02U
CPU
QnUD(H)
CPU
Built-in
Ethernet
port
QCPU
RUN ERR.
Program
error
SFC syntax
error
SFCP. FORMAT
ERR.
Switching from
STOP to RUN
Stop
Off
Flashi
ng
SFC block
execution error
BLOCK
EXE.ERROR
Execution of an
instruction
Stop
Off
Flashi
ng
SFC step
execution error
STEP
EXE.ERROR
Execution of an
instruction
Stop
Off
Flashi
ng
CPU
error
Watchdog error
supervision
WDT ERROR
•Always Stop
Off
Flashi
ng
Program time-
out
PRG.TIME OVER
•Always
Continue On On
Multiple
CPU
system
s error
Another CPU
major error
MULTI CPU
DOWN
•Always
Power-on/reset
Stop
Off
Flashi
ng
Multiple CPU
systems
execution error
MULTI
EXE.ERROR
Power-on/reset Stop
Off
Flashi
ng
Multiple CPU
systems
consistency
error
CPU LAY.
ERROR
Power-on/reset Stop
Off
Flashi
ng
Another CPU
minor error
MULTI CPU
ERROR
•Always
Continue On
On
File diagnostic check
INCORRECT
FILE
Power-on/reset
Switching from
STOP to RUN
Writing to
programmable
controller
Stop
Off Off
Annunciator check F****
Execution of an
instruction
Continue
On
USER
LED
turns
on.

Table of Contents