206
Item
Performance Specifications
Q61P-D
Mounting position Power supply module mounting slot
Applicable base unit Q3B, Q3DB, Q6B
Input power supply
*2
100 to 240VAC
(85 to 264VAC)
Input frequency 50/60Hz ±5%
Input voltage distortion
factor
Within 5% ( Page 103, Section 4.8.1)
Max. input apparent
power
130VA
Max. input power ----
Inrush current
*1
20A within 8ms
Rated output
current
5VDC 6A
24VDC ----
External output voltage ----
Overcurrent
protection
*1
5VDC 6.6A or more
24VDC ----
Overvoltage
protection
*1
5VDC 5.5 to 6.5V
24VDC ----
Efficiency 70% or more
Allowable momentary
power failure time
*1
Within 20ms
Dielectric withstand
voltage
2300VAC per minute (altitude 0 to 2000m)
Between the combined "line input/LG terminals" and the "FG terminal and output"
Insulation resistance
10MΩ or higher by 500VDC insulation resistance tester
Between the combined "line input/LG terminals" and the "FG terminal and output", the line input and
LG terminals, the output and FG terminals
Noise durability
• By noise simulator of 1500Vp-p noise voltage, 1µs noise width and 25 to 60Hz noise frequency
• Noise voltage IEC 61000-4-4, 2KV
Operation indication
LED indication (POWER LED, LIFE LED) ( Page 219, Section 7.2.5)
Fuse Built-in (User-unchangeable)
Contact output section
Application
ERR.
contact, LIFE OUT contact ( Page 188, Section 7.1)
Rated switching
voltage, current
24VDC, 0.5A
Minimum
switching load
5VDC, 1mA
Response time OFF to ON: 10ms max. ON to OFF: 12ms max.
Life
Mechanical : More than 20 million times
Electrical : More than 100 thousand times at rated switching voltage, current
Surge
suppressor
None
Fuse None
Terminal screw size M3.5
Applicable wire size
0.75 to 2mm
2
Applicable solderless
terminal
RAV1.25 - 3.5, RAV2 - 3.5, thickness 0.8mm or less. Two solderless terminals can be connected to one terminal.