450
CF10
H
iQ Sensor
Solution related
error
System error
Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
Check the connection status of each Ethernet
cable and the hub.
Check the line status of Ethernet.
Reset the CPU module and devices supporting
iQ Sensor Solution, and execute the function
again.
If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
QnUDV
LCPU
CF20
H
iQ Sensor
Solution related
error
The communication setting value is out of the
range.
The communication setting item not supported
by the target device supporting iQ Sensor
Solution is set.
The setting item required for the target device
supporting iQ Sensor Solution is not set.
Review the settings, and execute the function
again.
QnUDV
LCPU
CF30
H
iQ Sensor
Solution related
error
A parameter not supported by the target device
supporting iQ Sensor Solution was specified.
Check the version of the device supporting iQ
Sensor Solution.
QnUDV
LCPU
CF31
H
iQ Sensor
Solution related
error
System error
Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
Check the connection status of each Ethernet
cable and the hub.
Check the line status of Ethernet.
If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
QnUDV
LCPU
CF41
H
iQ Sensor
Solution related
error
The information required for monitoring cannot
be read from the device supporting iQ Sensor
Solution.
Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
Reset the devices supporting iQ Sensor
Solution, and execute the function again.
If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
QnUDV
LCPU
CF50
H
iQ Sensor
Solution related
error
System error
Check the operating status and connection
status of each device supporting iQ Sensor
Solution.
Check the connection status of each Ethernet
cable and the hub.
Check the line status of Ethernet.
Reset the CPU module and devices supporting
iQ Sensor Solution, and execute the function
again.
If the same error code is displayed again even
after the above actions are taken, please consult
the manufacturer of the device supporting iQ
Sensor Solution.
QnUDV
LCPU
CF51
H
iQ Sensor
Solution related
error
The function cannot be executed because the
function from another peripheral is being
executed.
Execute the function again after a while.
QnUDV
LCPU
Error code
(Hexadecimal)
Error item Error details Corrective action
Corresponding
CPU